3D Scanning

How accurate is 3D scanning? Our 0.04 mm figure explained

November 25, 2026

What a 0.04 mm scanning accuracy figure means and what it doesn't, plus how to work out the tolerance your part needs.

Illustration of a scanned surface as a fine grid of points, with a deviation highlighted in red and labelled 0.04 mm

TL;DR: 3D scanning accuracy is usually quoted as a single number measured under ideal conditions, and ours is 0.04 mm. It's a ceiling rather than a promise. The more useful question is what tolerance your part needs, and for most moulded and printed components the answer is looser than the scanner, because the part's own manufacturing variation is larger than the measurement error. This post explains both.

How accurate is 3D scanning? The question gets asked constantly and answered badly, usually with one number and no context.

We quote 0.04 mm. That figure is real and it's also the best case: a suitable surface, close range, controlled conditions. Published scanner specifications work the same way, and one buyer's guide puts it plainly, noting that manufacturers indicate maximums obtained under ideal conditions, so a lab figure isn't what you'll see in your own workshop.

The number matters less than most people assume, because it's rarely the limiting factor. A part moulded to a tenth of a millimetre doesn't get measured better by a scanner working to hundredths. Here's what the figures mean, and how to work out which one your job needs.

How accurate is 3D scanning?

Professional optical scanning typically measures small parts to somewhere between 0.02 mm and 0.1 mm on a good surface. Ours works to 0.04 mm. That applies to a suitable part at close range, and it gets worse as objects get larger, darker or shinier.

A single figure describes one measurement in good conditions, which is why single-point accuracy on its own tells you very little. It's a ceiling. Nobody hits their ceiling on a black rubber gasket in a warm workshop.

What it does tell you is which class of work a supplier is set up for. Our 3D scanning service sits in the range that suits engineering parts, replacement components and product development, and comfortably outside the range needed for certified aerospace inspection.

Accuracy, precision and resolution are three different things

They get used interchangeably in sales material and they mean completely different things.

Accuracy is how close a measurement is to the object's true size. Measure a 200 mm block and read 200.04 mm, and your accuracy is 0.04 mm.

Precision is consistency. Measure the same block five times and get 205.00 mm every time, and you're precise and wrong. As one metrology guide puts it, accuracy is closeness to actual dimensions while precision describes measurement consistency.

Resolution is how close together the measured points sit, sometimes called point distance. It controls detail rather than correctness. A scanner can have beautiful resolution and still measure the overall size wrongly.

Resolution should be matched to the feature, not maxed out. Guidance from scanner makers suggests a 5 cm feature needs resolution of 0.2 mm or better while a 20 cm feature can be captured at around 0.5 mm, and the two most common spec-sheet mistakes are confusing resolution with accuracy and scanning everything at maximum resolution.

What does our 0.04 mm figure mean?

It's the finest deviation our blue light and infrared equipment resolves on a suitable surface at close range. On a palm-sized matte component we expect to be near it. On a 1.5 metre panel, a mirror-finished casting or a matte black moulding, we won't be, and we'll say so at the quote stage.

Read it the way you'd read a machine's maximum speed. Useful for knowing what class of work it does. Not a promise about every job.

Three things move it. Size, because error accumulates as more scan passes get aligned across a larger object. Surface, because dark and reflective materials return less usable light. And conditions, because a warm workshop is not a measuring room.

What we do instead of quoting the ceiling is tell you the expected result for your specific part, and then prove it. The finished model gets compared back against the scan, and the deviation report goes out with the job. That's the number that means something, and it's why reverse engineering work should always come with one.

What tolerance does your part need?

Usually looser than the scanner. General injection moulding holds about a tenth of a millimetre on small features, widening to roughly half a per cent of the dimension on larger ones. Machined parts are tighter. In both cases the part's own manufacturing variation is bigger than a 0.04 mm measurement error.

The numbers are published. Moulding tolerances under the DIN 16742 framework run to around 0.5 per cent of nominal for commercial work and 0.2 per cent for fine work, because a moulded part shrinks between 0.3 and 2.5 per cent as it cools. Under the same standard's TG6 group, a plastic part is allowed ±0.07 mm at 1 to 3 mm nominal and ±0.31 mm at 80 to 120 mm. Tooling itself is typically machined to about ±0.127 mm.

Put that next to 0.04 mm. On a 100 mm moulded housing, the original process was allowed to vary by nearly eight times the measurement error of the scan. Chasing microns on a part like that is chasing the wrong thing.

Machined parts sit tighter, and the reference there is ISO 2768, which sets four general tolerance classes from fine to very coarse and applies to metal removal and sheet metal, though not to threads or surface roughness. Even at the fine end, general machining tolerances stay well above what optical scanning resolves on a small part.

The practical version: tell us what the part has to do rather than a number. Which faces mate, which holes take a bearing, how much movement the assembly forgives. Our product design team works backwards from that to the accuracy the job needs.

How a scanner's accuracy gets verified

There is a proper way to establish these numbers, and it's worth knowing it exists.

Optical scanners are tested against the VDI/VDE 2634 guideline, which sets out the artefacts and methods. For area-scanning systems the quality parameters are probing error, sphere-spacing error and flatness measurement error, measured on calibrated reference objects rather than on whatever happens to be on the bench.

The detail that shows how serious it is: the reference artefact itself has to be known to better than one fifth of the maximum error being measured, with a calibration certificate proving traceability to national standards. You cannot check a scanner with something less accurate than the scanner.

At the top of the market, figures get verified by an ISO 17025 accredited laboratory. That's the difference between a certified metrology figure and a manufacturer's claim, and it's the right question to ask any supplier quoting a number, including us.

What changes the accuracy you get on the day

Distance, surface, light and heat. Move the scanner further from the part and the same points spread across more area, so resolution and accuracy both fall. Dark and glossy surfaces return less usable data. And ambient conditions move the result more than the equipment does.

The distance effect is simple optics: the same number of points spread over a larger area reduces resolution and accuracy accordingly, which is why scanners are built for a working distance rather than being universal.

Everything else is the room. Research into optical digitisation lists temperature, humidity, lighting and dust alongside calibration, exposure and scanning angle as factors affecting the result. A workshop has all of those and controls none of them.

Which is the honest summary of this whole subject. The published figure is measured on a white test artefact in a controlled room. Your part is a worn black bracket. Both numbers are true and only one of them describes your job.

Two things to take away. Ask for the expected accuracy on your part rather than the scanner's headline figure, and ask for the deviation report that proves it afterwards. And check what tolerance the part was originally made to, because on most moulded and printed components the measurement was never the weak link.

Send us the part and tell us what it has to fit. We'll say what accuracy we expect to achieve on it before quoting, and the job can run through to industrial 3D printing or low volume manufacturing from there. Email sales@nexform.co.uk or use the contact form with a CAD file, a sketch or the part itself.

Written by

Scott Watts

Company Owner (Operations Manager)

Founder and owner of Nexform, leading every project from first enquiry to finished piece.

faq.

What does 0.04 mm accuracy mean in practice?

It's the finest deviation our equipment resolves on a suitable surface at close range, in good conditions. Treat it as a ceiling rather than a promise. On a small matte part we expect to be near it. On a large, dark or shiny part we won't be, and we'll tell you what to expect on your part before we start.

What's the difference between accuracy and resolution?

Accuracy is how close a measurement is to the object's true size. Resolution is how close together the measured points sit, which controls how much fine detail gets captured. A scanner can have very fine resolution and still measure the overall size wrongly. Both matter, for different reasons.

Is 3D scanning accurate enough to replace a moulded part?

Usually far better than it needs to be. General injection moulding holds around a tenth of a millimetre on small features and roughly half a per cent of the dimension on larger ones, so a scan at hundredths of a millimetre measures the part several times finer than the process that made it.

How do I tell you what accuracy I need?

Tell us what the part has to do rather than a number. Which faces mate with something else, which holes take a fastener or bearing, and how much movement the assembly tolerates. From that we can say what accuracy the job needs and whether it's achievable on that part.

How can I check a supplier's accuracy claim?

Ask which standard the figure was tested against, in what measuring volume, and by whom. A number verified against a standard like VDI/VDE 2634 by an accredited laboratory is evidence. A number on a web page with nothing behind it is marketing.

Do conditions change the accuracy I get?

Yes, and by more than most people expect. Surface colour and finish, part size, scanner distance, ambient light, dust and temperature all move the result. A figure measured on a matte white test artefact in a controlled room is the best case, not the typical one.

related posts

get in contact.

have an enquiry?
send a message.
Any file type, up to 500 MB
Message sent.


We will be in touch shortly.